Just one cylinder taken at random out of every lots of cylinders needs to be hydrostatically analyzed to destruction.

(two) Validate compliance of cylinder shells with all shell requirements; inspect inside before closing in the two finishes; verify heat therapy as good; receive all samples for all checks and for Verify analyses; witness all checks; confirm threads by gauge; report volumetric capacity and bare minimum thickness of wall noted.

(iv) With a steel plate connected to the top of the cylinder or long-lasting section thereof; ample Place have to be left within the plate to provide for stamping a minimum of six retest dates; the plate has to be no less than one⁄sixteen-inch thick and should be connected by welding, or by brazing.

(ii) One cylinder should be selected from Just about every lot and become hydrostatically pressure analyzed to destruction. If this cylinder bursts down below five (5) instances the services pressure, then two extra cylinders through the exact same ton as the previously tested cylinder have to be chosen and subjected to this exam.

(i) The word “spun” or “plug” need to be put close to the DOT specification marking when an conclusion closure during the finished cylinder has become welded by the spinning approach, or effected by plugging.

(iv) Permanent volumetric enlargement may not exceed ten % of the total volumetric enlargement at examination stress.

Reheat therapy of turned down cylinders is approved. Subsequent thereto, cylinders must go all prescribed tests to generally be suitable. Welds could possibly be fixed by ideal methods of fusion welding.

(i) The remaining cylinders from the great deal must be examined because of the proof stress, water-jacket, or immediate growth take a look at approach as prescribed in CGA C-one. The minimal exam stress must be taken care of for the precise timeframe and also the tests gear must be calibrated as prescribed in CGA C-1.

(iii) The minimum test pressure needs to be managed no less than thirty seconds and adequately more time to make sure complete expansion. Any internal tension utilized immediately after warmth-cure and ahead of the Formal test may not exceed 90 per cent from the exam force.

(1) Circumferential seams has to be by brazing only. Heads need to be connected to shells via the lap brazing technique and need to overlap not below four occasions the wall thickness. Brazing product should have a melting level of not below 1000 °F.

(iii) Straight threads, owning no less than four engaged threads, to own limited healthy and calculated shear power at the very least 10 periods the check strain with the container; gaskets required, ample to forestall leakage.

A person container taken at random out of two hundred or considerably less has to be hydrostatically analyzed to destruction. The rupture pressure needs to be bundled as part of the inspector's report.

(ii) Taper threads to get of size not below as specified for American Standard taper pipe threads.

(4) As a security precaution, In the event the company elects to make this take a look at before the hydrostatic exam, the producer shall design the website exam apparatus so the stress is placed on the smallest space practicable, throughout the stage of closure, and so as to use the smallest attainable volume of air or fuel.